Edison J. Cano,a,b Laure Flurin,b Abdelrhman Mohamed,c Kerryl E. Greenwood-Quaintance,b Yash S. Raval,bHaluk Beyenal,c Robin Patela,b
a Division of Infectious Diseases, Mayo Clinic, Rochester, Minnesota, USA
b Division of Clinical Microbiology, Mayo Clinic, Rochester, Minnesota, USA
c The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, Washington, USA
Edison J. Cano and Laure Flurin are co-first authors and contributed equally to this article. Author order was determined alphabetically.
ABSTRACT
Central line-associated bloodstream infection (CLABSI) contributes to mortality and cost. While aseptic dressings and antibiotic-impregnated catheters prevent some extraluminal infections, intraluminal infections remain a source of CLABSIs. In this proof-of-concept study, an electrochemical intravascular catheter (e-catheter) prototype capable of electrochemically generating hypochlorous acid intraluminally using platinum electrodes polarized at a constant potential of 1.5 electrode potential relative to saturated silver/silver chloride reference electrode measured in volts (VAg/AgCl) was developed. After 24 h of prepolarization at 1.5 VAg/AgCl, their activity was tested against clinical isolates of Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecium, and Escherichia coli derived from catheter-related infections. e-catheters generated a mean HOCl concentration of 15.86 6 4.03 mM and had a mean pH of 6.14 6 0.79. E-catheters prevented infections of all four species, with an average reduction of 8.41 6 0.61 log10 CFU/ml at 48 h compared to controls. Polarized e-catheters which generate low amounts of HOCl continuously should be further developed to prevent intraluminal infection. IMPORTANCE Catheter-related infections constitute an economic and mortality burden in health care. Several options are available to reduce the risk of infection, but only a few focus on preventing intraluminal infection, which occurs in long-term catheters, most often used for dialysis, prolonged treatment, or chemotherapy. A proto-type of a catheter called an “e-catheter” composed of three electrodes, capable of producing hypochlorous acid (HOCl) electrochemically in its lumen, was developed. When polarized at 1.5 V, chloride ions in the solution are oxidized to continuously produce low amounts of HOCl, which exhibits antibacterial activity in the lumen of the catheter. Here, this prototype was shown to be able to generate HOCl as well as prevent infection in a preliminary in vitro catheter model. This approach is a potential strategy for catheter infection prevention.
KEYWORDS catheter-related bloodstream infection, hypochlorous acid, electrochemistry, infection prevention.
Islam.I.Ragab1 Ahmed Kamal 2
1. Lecturer, Adult Medical Surgical Nursing Department, Faculty of Nursing, South Valley University, Qena, Egypt
2. Assistant Professor, Department of Plastic Surgery, Faculty of Medicine, Assiut University, Assiut Egypt
Abstract:
Introduction: Wound cleansing remains a corner stone in the management of diabetic foot ulcer. Hydrogen Peroxide (H2O2) and Povidone Iodine are topical antimicrobial agents but known to be toxic to cells involved in the wound healing cascade. The biggest challenge for the physicians and nurses is searching for a safe, non-cytotoxic and effective wound cleansing as Hypochlorous acid (HOCL). This study aimed to compare the efficacy of HOCL versus H2O2 followed by Povidine Iodine as a wound care agent in treating infected diabetic foot ulcers. Patients and methods: Design: used a randomized clinical trial design to compare the efficacy of HOCL versus H2O2 followed by Povidine Iodine as a wound care agent in treating infected diabetic foot ulcers.
Setting: This study was carried out in outpatient plastic and vascular surgery clinic at Assiut university Hospital.
Subjects: A random selection was performed on 60 patients with infected diabetic foot ulcers divided equally to control and study group. Methods: HOCL was used for the study group, as irrigate the wound with HOCL in a concentration; sterile Nacl 0.9% to HOCL 50.5% at ratio 8:2 and leave for 5 minutes, before covered the wound with sterile dressing. While H2O2 followed by Povidine Iodine used for the control group and the results were compared. Bacterial cultures were obtained before start washing, after five days thin each five days to the end of the study for the two groups.
Results: HOCL was able to be effective against Candida, Proteus, Klebsella, Psudomonas, and Methicillin resistant staphylococcus aureus (MARSA) compare to H2O2 and Povidine iodine. There is a statistically significant difference between using HOCL and H2O2 and Povidine iodine as a washing therapy in reducing bacterial count, wound pain, odor, discharge and improve wound healing in diabetic foot ulcer.
Conclusion: Hypochlorous acid is a potent antimicrobial cleanser against a wide range of microorganisms. Hypochlorous Acid is safe, low cost, painless, easy to perform, and improve wound healing or rapidly prepared diabetic foot ulcer for skin flap or graft. Recommendation: The study recommended use of HOCL as a virtuous diabetic wound care cleanser. Further research is needed on a larger scale to validate the effectiveness of Hypochlorous acid as a wound care agent in septic diabetic foot ulcers.
Keywords: Hypochlorous Acid, Hydrogen Peroxide, Infected diabetic foot ulcer, Povidine Iodine.
This article is excerpted from the 《Frontiers in Medicine》by Wound World
伤口世界平台生态圈,以“关爱人间所有伤口患者”为愿景,连接、整合和拓展线上和线下的管理慢性伤口的资源,倡导远程、就近和居家管理慢性伤口,解决伤口专家的碎片化时间的价值创造、诊疗经验的裂变复制、和患者的就近、居家和低成本管理慢性伤口的问题。
2019广东省医疗行业协会伤口管理分会年会
扫一扫了解详情:
任何关于疾病的建议都不能替代执业医师的面对面诊断。所有门诊时间仅供参考,最终以医院当日公布为准。
网友、医生言论仅代表其个人观点,不代表本站同意其说法,请谨慎参阅,本站不承担由此引起的法律责任。